15 kVA nominal AC output at 230 V / 50 Hz
30 kVA nominal AC output at 230 V / 50 Hz
60 kVA nominal AC output at 230 V / 50 Hz
Single-axle galvanized trailer
Gross Vehicle Weight: up to 750 kg
Dimensions: 2.4 × 1.5 m platform
Stabilizer jacks, rear reflectors, road-legal lighting kit
Road legal with number plates
Single-axle galvanized trailer
Gross Vehicle Weight: up to 2,000 kg
Dimensions: 3.5 × 1.7 m platform
Braked axles with overrun system
Heavy-duty jockey wheel, stabilizer legs, full road lighting kit
Road legal with number plates
Dual-axle galvanized trailer
Gross Vehicle Weight: up to 3,500 kg
Dimensions: approx. 5.2 × 2.2 m platform
Heavy-duty braked axles with overrun system
Hydraulic stabilizers and reinforced steel chassis
Road legal with lighting kit, reflectors, number plates
Load access doors for battery/inverter maintenance
4 × Jinko Tiger Neo N-type 590W non-foldable
Total nominal PV output: 2.36 kWh
Mounting: fixed-tilt aluminum frame (non-folding)
MPPT-ready wiring for optimal efficiency
8 × Jinko Tiger Neo N-type 590W foldable
Total nominal PV output: 4.72 kWh
Mounting: gas-assisted fold-out aluminum frame
Adjustable tilt angle
MPPT-ready wiring with combiner box and surge protection
12 × Jinko Tiger Neo N-type 590W foldable
Total nominal PV output: up to 7.08 kWh
Mounting: dual-sided fold-out frame with gas-assist arms
Adjustable tilt, lockable in transit
Surge protection (SPD Type II), fused combiner box, MC4-compatible wiring
Nominal capacity: 15.9 kWh
Chemistry: Lithium Iron Phosphate (LiFePO₄)
Nominal voltage: 24V
Peak discharge current: 300 A
Cycle life: >6,000 cycles @ 80% DoD
Integrated BMS with overvoltage, undervoltage, overcurrent and temperature protection
Option for parallel expansion of capacity
1000A T-type fuse for short-circuit protection
Hermetic filler
Nominal capacity: 31.8 kWh
Chemistry: Lithium Iron Phosphate (LiFePO₄)
Nominal voltage: 24 V
Peak discharge current: 300 A
Cycle life: >6,000 cycles @ 80% DoD
Integrated BMS with overvoltage, undervoltage, overcurrent and temperature protection
Option for parallel expansion of capacity
1000A T-type fuse for short-circuit protection
Hermetic filler
Nominal capacity: 63.6 kWh
Chemistry: Lithium Iron Phosphate (LiFePO₄)
Nominal voltage: 48 V
Peak discharge current: 300 A
Rack-mounted modular battery system
Cycle life: >6,000 cycles @ 80% DoD
Integrated BMS with advanced diagnostics, CAN communication
Expandable architecture for future scaling
1000A T-type fuse for short-circuit protection
Hermetic filler
Victron Multiplus-II or Huawei Hybrid Inverter
Rated output: 3 kW (pure sine wave)
AC input/output: 230 V single-phase
Battery-to-load and solar-to-load prioritization logic
Victron Quattro 24/8000 or Huawei Hybrid Inverter
Rated output: 8 kW (pure sine wave)
AC input/output: 230 V single-phase
Dual AC input (grid and generator)
Battery-to-load and solar-to-load prioritization logic
Dual Victron Quattro 48/10000 or Huawei Hybrid Inverter stack
Rated output: 10 kW (parallel operation)
AC input/output: 230 V single-phase or split-phase option
Grid/generator integration with smart transfer logic
Integrated MPPT (Victron SmartSolar 250/100 or Huawei SmartLogger)
Inverter-type diesel generator
Output range: 5 kW
Electric start, low-noise enclosure
Automatic start/stop via inverter trigger (optional)
Diesel generator (silent enclosed type)
Output range: 10 kW
Electric start, integrated ATS (automatic transfer switch)
Sound level: <70 dB at 7 m
Automatic start/stop via inverter trigger (optional)
Silent diesel generator (enclosed)
Output range: 15 kW
Integrated ATS (automatic transfer switch)
Fuel tank: 60–100 L base-mounted
Sound level: <65 dB at 7 m
Auto start/stop controlled by inverter or VRM system
Victron Cerbo GX + GX Touch 50
Remote monitoring via Victron VRM Portal (cloud + local)
Real-time status: solar input, load consumption, battery SoC, alarms
Victron Cerbo GX + GX Touch 50
Remote monitoring via Victron VRM Portal (cloud + local)
Real-time status: solar input, load consumption, battery SoC, generator state, alarms
Victron Cerbo GX + GX Touch 70
Remote monitoring via Victron VRM Portal (cloud + local)
Live performance metrics: solar production, generator runtime, load curves, battery diagnostics
Ethernet, Wi-Fi, and optional LTE connectivity
Historical data logging and remote firmware updates
~520–700 kg depending on battery and generator configuration
~1,200–1,400 kg depending on battery and generator configuration
Operating temperature: −10 °C to +50 °C
Ingress protection: IP65 (external enclosures)
Designed for outdoor use, high UV and salt spray resistance
Optional weatherproof storage compartment for accessories
Setup Time: <10 minutes by one person. Plug & play: pre-wired, pre-configured, ready to operate
Operating temperature: −10 °C to +50 °C
Ingress protection: IP65 (PV & battery enclosures)
Designed for outdoor use, UV and salt spray resistant
Optional weatherproof storage compartments
Setup Time: ~15 minutes by one person. Fold-out solar arms, pre-wired, ready to operate
Operating temperature: −10 °C to +50 °C
Ingress protection: IP65+ for PV, battery, and control compartments
Vandal-proof enclosure and lockable compartments
Certified lifting points (fork and crane compatible)
Setup Time: ~15 minutes by one person. Modular plug & play assembly with folding panels